logo
blog
BLOG DETAILS
Home > Blog >
Guide to Selecting Yoshitake GLV10 Manual Valves for Industrial Use
Events
Contact Us
Mr. Rambo
86-10-65569770
Contact Now

Guide to Selecting Yoshitake GLV10 Manual Valves for Industrial Use

2026-01-28
Latest company blogs about Guide to Selecting Yoshitake GLV10 Manual Valves for Industrial Use

In industrial piping systems, manual valves serve as critical control points—much like valves in human blood vessels regulate circulation. When these components malfunction, the consequences range from reduced productivity to catastrophic safety incidents. The YOSHITAKE GLV-10 series of manual valves, constructed from FCD (ductile cast iron), has established itself as a reliable solution for steam, air, water, oil, and other non-hazardous fluid systems. This technical analysis examines the valve's specifications, performance metrics, and selection criteria from an engineering perspective.

I. Core Specifications and Performance Metrics

The GLV-10 series distinguishes itself through operational reliability and material durability. Key technical parameters include:

  • Material Composition: FCD450 ductile cast iron provides superior tensile strength (450 MPa minimum) and elongation (10% minimum) compared to standard gray iron, offering 30-50% greater impact resistance in industrial environments.
  • Pressure-Temperature Profile: Rated for 1.4 MPa maximum working pressure and 220°C continuous service. Engineers must consult JIS B2051 pressure-temperature charts, as allowable pressure decreases by approximately 15% per 50°C increase beyond 150°C.
  • Connection Standard: JIS Rc (Japanese Industrial Standard tapered pipe threads) ensures leak-free joints in standard applications, though flange connections are recommended for pressures exceeding 1 MPa at elevated temperatures.
II. Dimensional Analysis Across Valve Sizes

The product line spans eight sizes from 8A (1/4") to 50A (2"), with dimensional characteristics that influence installation and flow capacity:

Nominal Size ΦD (mm) L (mm) H (mm) Mass (kg)
8A (1/4") 63 65 100 0.5
50A (2") 125 140 192 3.5

Flow capacity increases proportionally with valve size, with the 50A model providing approximately 6.5 times the flow area of the 8A variant. Weight escalates non-linearly due to thicker wall sections required for pressure containment in larger diameters.

III. Selection Methodology and Application Profiles

Proper valve selection requires evaluation of five critical parameters:

  1. Media Compatibility: Verify chemical resistance against fluid composition, particularly for acidic condensates in steam systems or additives in hydraulic oils.
  2. Hydraulic Requirements: Calculate required Cv (flow coefficient) values based on system flow rates and allowable pressure drops.
  3. Mechanical Constraints: Assess installation clearances, particularly in retrofit applications where existing pipe spacing may limit valve size.
  4. Operational Frequency: Manual operation proves cost-effective for infrequently adjusted systems, while automated alternatives may be preferable for dynamic control scenarios.

Common industrial implementations include:

  • Steam distribution networks in food processing facilities
  • Compressed air manifolds for manufacturing equipment
  • Hydraulic oil control in heavy machinery
  • Hot water circulation in district heating systems
IV. Technical Documentation and Support

Comprehensive engineering resources include CAD models (2D/3D), installation torque specifications, and pressure-temperature derating curves. These materials facilitate proper integration into piping system designs while meeting JIS B2001 valve testing standards.

V. Industry Outlook

While manual valves maintain importance in cost-sensitive and low-frequency applications, market trends indicate growing demand for intelligent control systems. Future product developments may incorporate position feedback and partial automation while retaining the GLV-10's mechanical reliability.

blog
BLOG DETAILS
Guide to Selecting Yoshitake GLV10 Manual Valves for Industrial Use
2026-01-28
Latest company news about Guide to Selecting Yoshitake GLV10 Manual Valves for Industrial Use

In industrial piping systems, manual valves serve as critical control points—much like valves in human blood vessels regulate circulation. When these components malfunction, the consequences range from reduced productivity to catastrophic safety incidents. The YOSHITAKE GLV-10 series of manual valves, constructed from FCD (ductile cast iron), has established itself as a reliable solution for steam, air, water, oil, and other non-hazardous fluid systems. This technical analysis examines the valve's specifications, performance metrics, and selection criteria from an engineering perspective.

I. Core Specifications and Performance Metrics

The GLV-10 series distinguishes itself through operational reliability and material durability. Key technical parameters include:

  • Material Composition: FCD450 ductile cast iron provides superior tensile strength (450 MPa minimum) and elongation (10% minimum) compared to standard gray iron, offering 30-50% greater impact resistance in industrial environments.
  • Pressure-Temperature Profile: Rated for 1.4 MPa maximum working pressure and 220°C continuous service. Engineers must consult JIS B2051 pressure-temperature charts, as allowable pressure decreases by approximately 15% per 50°C increase beyond 150°C.
  • Connection Standard: JIS Rc (Japanese Industrial Standard tapered pipe threads) ensures leak-free joints in standard applications, though flange connections are recommended for pressures exceeding 1 MPa at elevated temperatures.
II. Dimensional Analysis Across Valve Sizes

The product line spans eight sizes from 8A (1/4") to 50A (2"), with dimensional characteristics that influence installation and flow capacity:

Nominal Size ΦD (mm) L (mm) H (mm) Mass (kg)
8A (1/4") 63 65 100 0.5
50A (2") 125 140 192 3.5

Flow capacity increases proportionally with valve size, with the 50A model providing approximately 6.5 times the flow area of the 8A variant. Weight escalates non-linearly due to thicker wall sections required for pressure containment in larger diameters.

III. Selection Methodology and Application Profiles

Proper valve selection requires evaluation of five critical parameters:

  1. Media Compatibility: Verify chemical resistance against fluid composition, particularly for acidic condensates in steam systems or additives in hydraulic oils.
  2. Hydraulic Requirements: Calculate required Cv (flow coefficient) values based on system flow rates and allowable pressure drops.
  3. Mechanical Constraints: Assess installation clearances, particularly in retrofit applications where existing pipe spacing may limit valve size.
  4. Operational Frequency: Manual operation proves cost-effective for infrequently adjusted systems, while automated alternatives may be preferable for dynamic control scenarios.

Common industrial implementations include:

  • Steam distribution networks in food processing facilities
  • Compressed air manifolds for manufacturing equipment
  • Hydraulic oil control in heavy machinery
  • Hot water circulation in district heating systems
IV. Technical Documentation and Support

Comprehensive engineering resources include CAD models (2D/3D), installation torque specifications, and pressure-temperature derating curves. These materials facilitate proper integration into piping system designs while meeting JIS B2001 valve testing standards.

V. Industry Outlook

While manual valves maintain importance in cost-sensitive and low-frequency applications, market trends indicate growing demand for intelligent control systems. Future product developments may incorporate position feedback and partial automation while retaining the GLV-10's mechanical reliability.

sitemap |  Privacy Policy | China Good Quality Trunnion Mounted Ball Valve Supplier. Copyright © 2020-2026 Beijing Silk Road Enterprise Management Services Co.,LTD. . All Rights Reserved.