Product Details:
|
Power: | Manual | Material: | Stainless Steel |
---|---|---|---|
Media: | LO2,LN2,LAr,LNG,etc | Connection: | Flange |
Pressure: | Medium Pressure | Color: | Customer's Request |
High Light: | PN 4MPa Bonnet Ball Valve,LNG Flange Type Ball Valve,PN 4MPa Flange Type Ball Valve |
Extended Bonnet Ball Valve PN25 DN15 to DN200 Flange Type LNG Ball Valve
The cryogenic valve is a kind of valve used under the conditions with temperature below -196℃. The products include cryogenic ball valves, gate valves, globe valves and cryogenic check valves. The cryogenic treatment and prolonged stem design are adopted to ensure the performance. They are suitable for liquefied natural gas, liquefied gas, petroleum gas and etc.
Body material and applicable temperature:
ASTM A352 LCB ≥ -46C
ASTM A352 LCC ≥ -46C
ASTM A351 CF8 ≥ -196C
ASTM A351 CF8M ≥ -196C
Executive Standard: API6D API600 API598
Our Product
Main technical parameters Nominal diameter: DN10-250mm
Nominal Pressure: PN4.0MPa
Applicable medium: O2, N2, Ar, LNG
Applicable temperature: -80℃~+80℃
Connecting format:
Material: Body: CF8 Bonnet: 06Cr19NI10
Stem: 06Cr19NI10 Packing: PTFE Disc face ring:PCTFE
Service
For your company to order valve products in our company, our factory makes the following commitments in terms of after-sales service:
1. Our company implements warranty on product quality;
2. After the contract is signed, guarantee the quality and quantity, and deliver on time;
3. The company ensures that the valve products provided meet the contract targets
4. For technical consultation of the demand side, give answers at any time;
5. When delivering the equipment, the factory delivers the following materials to the purchaser: delivery list, product certificate, product sample, product instruction manual, technical information;
After receiving a letter or a phone call from the user regarding quality issues, we guarantee a response within 24 hours to resolve the issue as quickly as possible
Notes When Use
Notes When Use
1 . It should ensure that the pipe is blown clean before installation.
2 . When installing, make sure that the flow direction indicated by the arrow on the valve body should be consistent with the flow direction of the fluid.
3 . This valve has been degreased. Store and keep clean when installing.
4 . After the pipeline construction is completed, all the valves on the pipeline should be opened, and the residue in the pipeline should be thoroughly and thoroughly kept to ensure that the pipeline system is clean and free of debris.
5 . The installation system diagram with the oil-free requirements should be degreased.
6 . Slowly open and close during use.
7 . If the precision parts such as the valve disc, valve seat and valve stem are worn or damaged, it must be repaired and replaced in time.
8 . For parts such as gaskets and sealing materials, replace them with new ones each time.